An investigation on CO₂ concentration based on field survey and simulation in naturally ventilated Nepalese school buildings during summer
https://tcu-ar.repo.nii.ac.jp/records/2000087
https://tcu-ar.repo.nii.ac.jp/records/20000870e5a41d3-8091-49e4-9f58-ce933d893515
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2024-01-26 | |||||
タイトル | ||||||
タイトル | An investigation on CO₂ concentration based on field survey and simulation in naturally ventilated Nepalese school buildings during summer | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Classroom | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Natural ventilation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | CO₂ emission rate | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | CO₂ mass balance | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Number of air change (ACH) | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
著者 |
スレスタ, ミサン
× スレスタ, ミサン× リジャル, ホム バハドゥル× 加用, 現空× 宿谷, 昌則 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Natural ventilation is usually adopted to provide required indoor air quality (IAQ) and thermal comfort. IAQ to be represented by CO₂ concentration and ventilation is correlated with the academic performance of students. Most Nepalese school buildings are relying on natural ventilation through windows and have no glass sheets within them. This study is assessing the ventilation performance in those buildings that has not yet been known, through the measurement of CO₂ concentration and questionnaire survey during the summer of 2019 in three schools located in the temperate climate of Nepal. The indoor CO₂ concentration was much lower than the acceptable limit. Most students accepted the IAQ under such condition of classrooms. Based on the transient mass balance, a numerical simulation method was developed for estimating the number of air change per hour (ACH) and the indoor CO₂ concentration. The estimated ACHs were found higher than 25 h−1 and thereby confirmed that ventilation was performed very well. The indoor CO₂ concentrations simulated using the estimated ACHs were compared and found well fit with the measured CO₂ concentration. The simulation of how the reduction of the ACH to a half or a quarter affects the indoor CO₂ concentrations was conducted and found that the CO₂ concentration would be still quite low in these schools. The findings in this study should be useful for assessing the ventilation performance after the installation of glass windows to be necessary at one of the highest priorities is made in the future. | |||||
言語 | en | |||||
書誌情報 |
en : Building and Environment 巻 207, Part A, 号 108405, p. 1-13, ページ数 13, 発行日 2021-10-19 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
言語 | en | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0360-1323 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1016/j.buildenv.2021.108405 | |||||
権利 | ||||||
言語 | en | |||||
権利情報 | © 2021 Elsevier Ltd. All rights reserved. | |||||
関連サイト | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/am/pii/S0360132321008027 | |||||
関連名称 | https://www.sciencedirect.com/science/article/am/pii/S0360132321008027 | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |